LUNA-FL™ 具有四种计数模块,是我们的强大动力。配备明场和双荧光光学元件,可灵敏检测除细菌外的大多数细胞类型。LUNA-FL™ 可以将原代细胞(如 PBMC、脾细胞、中性粒细胞和干细胞)与不需要的碎片区分开来,以获得准确的细胞计数和活力结果。明场细胞计数、荧光细胞计数、酵母细胞计数和 GFP 转染分析都在 LUNA-FL™ 仪器中。这款多功能小巧细胞计数仪可方便地放置在细胞培养室或您的工作台上,以无缝融入您的工作流程。
Great performance, would recommend for other researchers!
Easy to use, saves us time and offers good quality. The consultant Dr Eberhardt was also professional and patient to teach us before use.
University Heidelberg
Great instrument, I like using it. Really helpful.
The device is easy to use, I mainly use it before cell seeding or to check for my culture's viability and survival. The results are reproducible and the device provides fast results. The accuracy seems to be great as well.
BGU
Brain Cancer Cell-derived Exosomes Protect Scopolamine-Induced Death of SH-SY5Y Neuron Cells.
2021. Lee M. International Journal of Health Sciences and Research 10.36838/v3i1.8.
The Type and Source of Reactive Oxygen Species Influences the Outcome of Oxidative Stress in Cultured Cells.
2021. Goffart S, Tikkanen P, Michell C, Wilson T, Pohjoismäki JLOLO. Cells 10(5):1075.
Immune Memory in Mild COVID-19 Patients and Unexposed Donors Reveals Persistent T Cell Responses After SARS-CoV-2 Infection.
2021. Ansari A, Arya R, Sachan S, Jha SN, Kalia A, Lall A, Sette A, Grifoni A, Weiskopf D, Coshic P, Sharma A, Gupta N. Frontiers in Immunology 12:636768.
The Small GTPase Arf6 Functions as a Membrane Tether in a Chemically-Defined Reconstitution System.
2021. Fujibayashi K, Mima J. Frontiers in Cell and Developmental Biology 9:628910.
Flow cytometric quantification of apoptotic and proliferating cells applying an improved method for dissociation of spheroids.
2021. Metzger W, Rösch B, Sossong D, Bubel M, Pohlemann T. Cell Biology International 10.1002/cbin.11618.
2022-04-07 | 2.12 MB
2022-04-07 | 2.14 MB
2018-04-16 | 110 KB
2018-04-16 | 284 KB
2018-04-16 | 1.7 MB
2018-04-13 | 906 KB
2018-04-16 | 403 MB
2018-04-16 | 862 KB
2018-04-16 | 476 KB
2018-04-13 | 665.84 KB
2018-04-13 | 720.79 KB
Cat # | Product | Qty |
---|---|---|
L20001 | LUNA-FL™ Automated Fluorescence Cell Counter | 1 unit |
L12005 | PhotonSlide™, 50 Slides | 1 box |
L12006 | PhotonSlide™, 500 Slides | 10 boxes |
L12007 | PhotonSlide™, 1000 Slides | 20 boxes |
L12001 | LUNA™ Cell Counting Slides, 50 Slides | 1 box |
L12002 | LUNA™ Cell Counting Slides, 500 Slides | 10 boxes |
L12003 | LUNA™ Cell Counting Slides, 1000 Slides | 20 boxes |
L12011 | LUNA™ Reusable Slide | 1 unit |
L12012 | LUNA™ Reusable Slides | 2 units |
L12014 | LUNA™ Reusable Slide Coverslips | 10 units |
T13001 | Trypan Blue Stain, 0.4% | 2 X 1 mL |
L13002 | Erythrosin B Stain | 2 x 1 mL |
F23001 | Acridine Orange/Propidium Iodide Stain | 2 x 0.5 mL |
F23002 | Acridine Orange Stain | 2 x 0.5 mL |
F23003 | Propidium Iodide Stain | 2 x 0.5 mL |
F23202 | Yeast Viability Kit 1 - Propidium Iodide Stain for Yeast (1 x 0.5 mL) - Fluorescein Diacetate Stain (1 x 0.5 mL) - Cell Dilution Buffer (1 x 20 mL) - Fluorescence Signal Enhancer 1 (1 x 0.5 mL) | 1 kit |
F23212 | Cell Dilution Buffer | 5 x 20 mL |
F23102 | LUNA™ Fluorescence Calibration Beads | 1 x 0.5 mL |
B13101 | LUNA™ Standard Beads | 2 x 1 mL |
F24003 | LUNA-FL™ IQ/OQ Protocol | 1 copy |
P10001 | LUNA™ Printer I | 1 unit |
P12001 | LUNA™ Printer I Paper (Thermal, 275 prints/roll, 6rolls) | 3 x 2 rolls |
Sample Volume | 10 μl |
Cell Counting Time | 30 sec |
Cell Concentration Range | 5×104 – 1×107 cells/mL |
Cell Size Range | Detectable Range: 1 – 90 μm Optimal Range: 5 – 60 μm |
Excitation wavelength | 470 ± 20 nm |
Emission wavelength | 530 ± 25 nm, 600 nm (LP) |
Light Source | LED |
Image Resolution | 5 MP |
LCD Display | 800 x 480 pixels |
Dimensions (W×D×H) | 22 × 21 × 9 cm (8.6 × 8.3 × 3.5 in) |
Weight | 1.8 kg (4 lb) *without the AC adapter and power cord |